1. Dismount the pulley cover and turn the pulley q until the pulley scale indicates 180˚ and the
needle bar is set at the lowest position. (The pulley " " mark and the stop mark " " are
aligned.)
2. Insert the positioning bar w into the hole of the pulley q and fix the drive shaft.
Note) Turn the pulley securely in the clockwise direction to eliminate a backlash.
3. Loosen the needle bar clamp set screw e when the needle tip is positioned 10.8 mm above
the center of the rotary hook shaft. Adjust the position of the needle bar thread guide so that
the set screw r on it is turned to the right by 25 ~ 30˚. Tighten the needle bar clamp set
screw e securely.
Note) When tightening the needle bar clamp set screw e, the hole in the needle bar guide should face the front.
4. After adjustment is finished, remove the positioning bar w.
5. Set the needle bar at the highest position (where the pulley indication mark "
cover indication mark "
the cushion rubber y, and tighten the top dead center stopper screw u while pressing down
the needle bar clamp so that it faces the front.
Note) Make sure that the top dead center stopper does not hit the needle bar guide rail i at this time.
" are aligned). Lightly press the top dead center stopper t toward
BES-940BC • BES-1240BC
Chapter 10 Standard Adjustment
" and the
237