Precautions for installation

Panasonic assumes no responsibility for injuries or property damage resulting from fail-
ures arising out of improper installation or operation inconsistent with this documenta-
tion.
This product is designed to be installed
under eaves.
Install the product under eaves to avoid direct
sunlight.
Installing place
Contact your dealer for assistance if you are
unsure of an appropriate place in your particu-
lar environment.
• Make sure that the installation area is
strong enough to hold this product, such
as a concrete ceiling.
• Install the camera in the foundation area of
the architecture or where sufficient strength
is assured.
• If a ceiling board such as plaster board is
too weak to support the total weight, the
area shall be sufficiently reinforced.
Do not place this product in the following
places:
• Locations where a chemical agent is used
such as a swimming pool
• Locations subject to moisture or oil smoke
such as a kitchen
• Locations that have a specific environment
that is subject to an inflammable atmo-
sphere or solvents
• Locations where a radiation, an X-ray, a
strong radio wave or a strong magnetic
field is generated
• Locations where corrosive gas is pro-
duced, locations where it may be damaged
by briny air such as seashores
• Locations where the temperature is not
within the specified range (page 37)
• Locations subject to vibrations that exceed
the railway specifications (EN50155)
Do not install this product in a humid or
dust-laden environment.
Otherwise, lifetime of the internal parts may be
shortened.
Be sure to remove this product if it is not
in use.
Shielded (STP) LAN cables must be used
with this unit to ensure compliance with
EMC standards. *
* E models only
Design and engineer the power supply
system to turn on/off the power of this
product.
The product has no power switch. When
installing the product, use a power supply
device equipped with the ON-OFF switch for
servicing.
About the network connection
When connecting to a network using the net-
work cable of this product, observe the follow-
ing.
• When wiring for the network, design and
engineer not to be affected by thunder.
Screw tightening
• The screws and bolts must be tightened
with an appropriate tightening torque
according to the material and strength of
the installation area.
• Do not use an impact driver. Use of an
impact driver may damage the screws or
cause tightening excessively.
• Tighten screws at a right angle to the sur-
face. After tightening screws, perform
checks to ensure that the tightening is suf-
ficient enough so that there is no move-
ment or looseness.
13