Guide To Service; Icemaker Cleaning And Sanitizing Procedures; Maintenance; Monthly - Cornelius UC 701 SERIES Installation And Service Manual

Continuous flow icemaker
Table of Contents

Advertisement

!
WARNING:
Disconnect electrical power to the Icemaker to prevent personal injury before attempting any internal maintenance.
Only qualified personnel should service internal components or electrical wiring.
Failure to Comply Could Result in Serious Injury, Death or Equipment Damage.
I
C
CEMAKER
LEANING AND
!
CAUTION:
Do not use any of the ice made during cleaning operations. Clean and sanitize ice storage area when cleaning
icemaker.
1. Turn machine off.
2. Shut off water supply.
3. Remove ice from storage bin.
4. Mix approved cleaner (2 gallons as directed). Recommended cleaner: Calgon Corp. of Virginia Chemicals,
ice machine cleaner. Mixture: 3-1/3 ounces per gallon of water.
5. Clean auger assembly and ice transition tube in a sink using cleaner mixture and reinstall in icemaker.
6. Turn machine on and add cleaner solution to water level control until 2 gallons have been used.
7. Turn on water supply and run machine for 15 minutes.
8. Turn off machine and remove all ice.
9. Sanitize using household liquid bleach (50 ppm chlorine). Mixture: 1 fluid ounce per gallon room temperature
water. 2 minute exposure time.
10. Sanitize auger assembly and ice transition tube in a sink using sanitizing solution and reinstall in icemaker.
11. Fill icemaker with sanitizer by slowly pouring solution into water feed reservoir until full. Solution will drain
through overflow tube. Do not run machine. Allow to air dry.
12. If icemaker is used in conjunction with ice dispenser or storage bin, follow manufacturer's recommended clean-
ing instructions at this time.
M
AINTENANCE
Preventive maintenance can increase the trouble free life of your icemaker. Many authorized service agencies offer
service contracts for your icemaker. Contact your local distributor for further information.

Monthly

1. Clean the condenser. Use a brush, vacuum cleaner or blow from inside with air or CO
2. Inspect water feed reservoir at lease once a month until a definite pattern for cleaning and sanitizing has been
established.
© 2000-2012, IMI Cornelius Inc.
UC 701 Series Continuous Flow Icemaker Installation and Service Manual

GUIDE TO SERVICE

S
P
ANITIZING
- 9 -
ROCEDURES
gas.
2
Publication Number: 630460150

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ucr701-aUcr701-w

Table of Contents