Standard Specifications

Rating

200V class
Type FR-F720-
Applied motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply system capacity (kVA)
Protective structure (JEM 1030)
Cooling system
Approx. mass (kg)
400V class
Type FR-F740-
Applied motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply system capacity (kVA)
Protective structure (JEM 1030)
Cooling system
Approx. mass (kg)
Type FR-F740-
Applied motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply system capacity (kVA)
Protective structure (JEM 1030)
Cooling system
Approx. mass (kg)
*1. The applied motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2. The rated output capacity indicated assumes that the output voltage is 220V for 200V class and 440V for 400V class.
*3. When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter output
current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.
*4. The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,
allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the pulse voltage value of the inverter output side voltage remains unchanged at about
*6. The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*7. When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type (IP00).
*8. FR-DU07 : IP40 (Except for the PU connector).
7
K
0.75
1.5
2.2
0.75
1.5
2.2
*1
1.6
2.7
3.7
4.2
7.0
9.6
(3.6)
(6.0)
(8.2)
2.5
4.5
5.5
*6
*8
Self-cooling
1.8
2.2
3.5
K
0.75
1.5
2.2
0.75
1.5
2.2
*1
1.6
2.7
3.7
2.1
3.5
4.8
(1.8)
(3.0)
(4.1)
2.5
4.5
5.5
*6
*8
Self-cooling
3.5
3.5
3.5
K
75
90
110
75
90
110
*1
110
137
165
144
180
216
(122)
(153)
(183)
110
137
165
*6
*8
37
50
57
3.7
5.5
7.5
11
15
18.5
3.7
5.5
7.5
11
15
18.5
5.8
8.8
11.8 17.1 22.1
27
15.2
23
31
45
58
70
(13)
(20)
(26)
(38)
(49)
(60)
120% 60s, 150% 3s (inverse time characteristics)
Three-phase 200 to 240V
Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz
170 to 242V 50Hz, 170 to 264V 60Hz
±5%
9
12
17
20
28
34
Enclosed type (IP20)*7
Forced air cooling
3.5
3.5
6.5
6.5
7.5
13
3.7
5.5
7.5
11
3.7
5.5
7.5
11
5.8
8.8
12.2
17.5
7.6
11.5
16
23
(6.4)
(9.8)
(13)
(19)
120% 60s, 150% 3s (inverse time characteristics)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
9
12
17
20
Enclosed type (IP20)
*7
3.5
3.5
6.5
6.5
132
160
185
220
250
132
160
185
220
250
198
247
275
329
366
260
325
361
432
481
(221)
(276)
(306)
(367)
(408)
120% 60s, 150% 3s (inverse time characteristics)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
198
247
275
329
366
Open type (IP00)
Forced air cooling
72
72
110
110
220
22
30
37
45
55
22
30
37
45
55
32
43
53
65
81
85
114
140
170
212
(72)
(97)
(119)
(145)
(180)
41
52
65
79
99
Open type (IP00)
13
14
23
35
35
15
18.5
22
30
37
15
18.5
22
30
37
22.1
26.7
32.8
43.4
53.3
29
35
43
57
70
(24)
(30)
(36)
(48)
(60)
28
34
41
52
66
Open type (IP00)
Forced air cooling
7.5
7.5
13
13
23
280
315
355
400
450
280
315
355
400
450
416
464
520
586
659
547
610
683
770
866
(464)
(518)
(580)
(654)
(736)
416
464
520
586
659
220
220
260
260
370
that of the power supply.
2
75
90
110
75
90
110
110
132
165
288
346
432
(244)
(294)
(367)
110
132
165
67
70
70
45
55
45
55
64.8
80.8
85
106
(72)
(90)
80
100
35
35
500
560
500
560
733
833
962
1094
(817)
(929)
733
833
370
370

Hide quick links: