EPSON Stylus COLOR 880
Be sure to perform the following adjustments after replacing
the Main Board;
1. Head voltage ID Input (Refer to Chapter 5.)
2. Bi-D adjustment, including Head Gap Adjustment (Refer
to Chapter 5.)
3. USB ID data input (Refer to Chapter 5.)
Be sure to exchange the following parts also when replacing
the Main Board;
1. Waste Ink Absorption Pad
2. Ink Cartridge (BK & Color)
This parts exchange is required since the several ink
counters stored in the EEPROM are lost when the Main Board
is replaced.
Make sure each cable is set in the correct cable holder (A or
B) on the M/B Shield Plate. Refer to Figure 4-5.
PF Encoder Sensor FFC
Panel FFC
Cable Holder A
PE Detector Cable and
ASF HP Sensor Cable
Figure 4-5. Setting the Cables to Holders A and B
Disassembly and Assembly
Cable Holder B
Two Head FFCs
ASF/Pump
CR Motor and PF
Motor Cable
Motor Cables
Disassembly Procedures

4.2.3 Removing the Operation Panel

The panel board equipped with printer is as follows:
- Stylus COLOR 880:
1) Remove the Upper Housing. (Refer to Section 4.2.1.)
2) Remove one screw (No.1) securing the Operation Panel Assembly.
Disconnect the Operation Panel Assembly from the Printer Mechanism.
Refer to Figure 4-6.
3) Remove two screws (No.3) and detach the Sub Right Panel Housing from
the Operation Panel Assembly.
4) Remove the Panel Shield Plate and the C298PNL board from the
Operation Panel Assembly.
5) Disconnect the Panel FFC from the connector on the C298PNL board.
Removing the Operation Panel Assembly also separates the
stacker assembly from the Printer Mechanism, since the
Stacker Assembly is held with Operation Panel.
Revision A
C298PNL
85