1.6.7 Initialization Items and Values

The values used when this printer is initialized are described under Default Settings . Values set through
the default setting mode or the remote control codes are, however, stored as initialization values only after
power off. On the other hand, values set by other methods are cleared at power off, and the printer returns
to the initialization values shown in the table when the printer is initialized.
Initialization Item
Print direction
Font
Pitch
I/F
Auto I/F wait mode
Software
Auto CR (IBM mode only)
AGM (IBM mode only)
Character table
Character table for NLSP
Auto line feed
Network I/F mode
Loading position
Economy mode
Parallel l/F mode
Line spacing
Page length
Y: Stored after the printer is powered Off.
E: Effective only while printer power is On.
N: Cannot change.
Rev. A
Table 1-29. Initialization Values
Default Set
by Panel Operation?
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
EPSON Control Codes?
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
N
Y
Y
N
E
Y
Product Description
Factory Value
Auto
Courier
10 cpi
Auto
10 seconds
ESC/P 2
Off
Off
PC437
PC437
OFF
Off
8.5 mm
OFF
Fast
4.23 mm (1/6 inch)
Maximum
1-25