EPSON Stylus C60
Indicators
Printer status
Power
No ink cartridge
On
(Black and Color)
Ink end error
On-> Blink
On -> Blink2
" A -> B " : A is a indicator condition when the CR unit is in the home position.
B is a indicator condition in the ink replacement sequence.
Blink : On 0.5sec + Off 0.5sec
Blink2 : On 0.2sec + Off 0.2sec + On 0.2sec + Off 0.4sec
Troubleshooting
Table 3-3. Error indication and status monitor 3
Error
On
[Bk I/C]
On -> Blink
[Col I/C]
Troubleshooting with LED Error Indications and Status Monitor 3 Message
Status monitor 3 message
Revision A
Condition for error detection
This error is detected when ;
1) the ink cartridge is not installed to the CR
unit.
2) the ink cartridge is defective.
This error is detected when ;
1) the ink consumption amount reaches 100%
2) the ink cartridge is defective.
[Note]
The slight amount of the ink is remaining in the
I/C even if the ink end error is detected. This is
to prevent the Printhead nozzle from the
printing operation without firing the ink.