2.3.7
Balance weight
1
Caution: Danger of injury !
Turn off the main switch.
Check and set the balance weight only when the machine is switched
off.
Standard checking
The balance weight 1 has to be positioned in a way that, with the
handwheel in position "210°", a stuck in Allen key 3 stands parallel to
the bed plate 2.
–
Check the position of the balance weight.
Correction
–
Loosen the screws on the balance weight 1.
–
Turn the balance weight 1 accordingly.
–
Tighten the threaded pin on the balance weight 1.
3
2
GB