3.2

Removing and replacing the clamp plates

1
Caution: danger of injury
The clamp plates 1 must be removed and replaced with the machine
switched off or in the "firm hold" position. Inadvertently operating the
pedal with the main switch turned on may lead to damage or injury.
Removing the clamp plates
Slightly raise the right or left (depending on the subclass) clamp
plate 1 and remove it forwards.
Slightly raise the other clamp plate 1 and remove it forwards.
Fitting the clamp plates
First fit the left or right clamp plate 1.
The pin 2 must engage in the jaws 3.
Then fit the second clamp plate 1.
The pin 2 must engage in the jaws 3.
2 3
1
11