Ventilation Requirements - CDA HCG 730 Users operating instructions Operating & Installation Instructions Manual

Table of Contents

Advertisement

The appliance should be installed into a room or space with an air supply in accor-
dance with BS 5440-2: 2000.
For rooms with a volume of less than 5 m
area will be required.
For rooms with a volume of between 5 m
2
50 cm
free area will be required unless the room has a door which opens directly to
the outside air in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m
NB. Regardless of room size, all rooms containing the appliance must
have direct access to the outside air via an openable window or
equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation require-
ments.
The above requirements allow also for use of a gas oven and grill but if there are
other gas burning appliances in the same room, consult a qualified engineer.
20

Ventilation requirements

3
- permanent ventilation of 100 cm
3
3
and 10 m
a permanent ventilation of
3
- no permanent ventilation is required.
2
free