Sharpening Or Replacing The Blades - Duerkopp Adler 271 Service Manual

Table of Contents

Advertisement

10.3 Sharpening or replacing the blades

2
6
46
1
Regulation and inspection
The blade should cut reliably with the minimum possible pressure.
Caution: danger of injury
Turn off the main switch.
Replace the blade with the sewing machine switched off.
Replacing the upper blade
Undo screws 4 and 5.
Remove upper blade 2 or 3.
Sharpen the upper blade.
IMPORTANT
Only the surface marked with the arrow may be sharpened.
Replace the upper blade.
Retighten screws 4 and 5.
Carry out a manual cutting test and if necessary re-adjust the
upper blade as described in section 9.
Check the blade overlap at TDC.
If sharpening the upper blade has made it too short (the tip no
longer makes contact with the lower blade) a new blade must be
fitted.
Replacing the lower blade
Remove the slider, foot and needle plate.
Undo 2 screws 1.
Remove lower blade 6.
Sharpen the lower blade.
IMPORTANT
Only the surface marked with the arrow may be sharpened.
Replace lower blade 6.
The cutting edge must make contact with the upper blade.
Retighten 2 screws 1.
Replace the slider, foot and needle plate.
2
3
4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

272273274275

Table of Contents