Dometic RM24A Service Manual page 8

Refrigerator for recreational vehicles
Table of Contents

Advertisement

8
When installing the refrigerators full consideration should be taken to t h e s e a l i n g
instructions and the specified minimum clearances and ventilation heights tabled
below:
Figure showing
the
location of the
clearances
MINIMUM VENTILATION HEIGHT
R e f r i g e r a t o r
model
KM24
RM36C
RM46, RM47
RM66, RM67
RM76, RM77
PROPER VENTING IS REQUIRED TO ENSURE BEST PERFORMANCE
Kit No. 1 - RM24
comprising:
side vent (Dometic 123)
Upper
Lower side vent (Dometic 183)
(see Fig. 4)
MINIMUM INSTALLATION CLEARANCES IN INCHES
Clearances
s i d e s , top and
bottom
Clearance A from
the rear of storage
compartment
Clearance B from
rear of
condenser
Fig. 3
Clearance C on
top of
condenser
FIGURES
I n s t a l l a t i o n t y p e
Kit No, 1
Kit No. 2
22 9/16"
37 l/16"
39 5/8"
47 l/2"
70 l/4"
Refrigerator model
o n
1
See minimum ventilation
height figures
Kit No. 3
29"
32"
41"
59"
UPPER VENT
Fig. 4
RM66 RM76
RM67 RM77
VENTILATIOX