The Gas Burner - Dometic RM24A Service Manual

Refrigerator for recreational vehicles
Table of Contents

Advertisement

THERMOSTAT REPLACEMENT
To replace the thermos tat, remove capillary from its clamp on the fresh food
evaporator fins, Remove the two sealing plugs, one on the outside and one on the
inside of the cabinet. Straighten the capillary and pull it through the cabinet,
Remove the thermostat by mscrewing it from the gas filter and the flame failure
s a f e t y d e v i c e .
Always, shut off the gas supply before removing any gas part from the
NOTE :
r e f r i g e r a t o r ,
By-pass screw sizes and part No.
RM46 ,RM47
The burner has the jet horizontally
located and the burner mixing tube is
formed as a bend with vertical outlet.
The pri<mary air inlets are pre-set and
therefore not adjustable. The burner
and the burner holder are made in one
p i e c e .
The burner is provided with the thenno-
electric failure safety device and the
thermocouple tip is pre-set.
To check for a correct flame, set thermostat to "!AX". Flame should have a bright
blue crown at the base of the flame.
Burner jet sizes and input BTU/h.
Part Ko.
Mode 1 Butane
RM24
24
289 00 39-lG/6
34
200 26 60-15/3
43
200 26 60-16/l'
51
200 26 60-1719
5 1
200 26 60-17/9
By-pass
Part No.
screw
14
34 19 13-14/3
17 28 19-02/l
17 28 19-02/l
s17
17 28 1+02/l
17 28 19-02/l
s17
Propane
24
43
200 26 60-1719
51
200 36 60-1817
52
53
200 26 GO-19/5
Fig. 55
Part Ko.
Input BTU/h
600
1000
1100
1200
1360
33
Fig. 54