26
Replacement of absorption unit on models RM76, RM77
When
replacing the absorption unit it will be necessary to remove the refrigerator
from
its recess (paragraph 10).
Remove the 6 screws at the bottom of the freezer compartment ("A" fig. 47).
1.
2.
Remove the thermostat capillary tubes by loosening the two screws "B" on the
e v a p o r a t o r f i n s ( f i g . 4 7 ) .
CAUTION :
The locations of the thermostat capillary tubes should be noted at this time
f o r r e l o c a t i o n l a t e r o n . The tubes must be replaced in the right position,
otherwise improper performance may result,
Remove the two sealing plugs for capillary tubes, one on the back and one in-
3.
side the cabinet, and straighten the tubes out.
4 .
Remove the capillary tubes by going to the back of the refrigerator and gently
pulling the tubes straight out,
Fig. 46