7. Lock Duration: Selects the duration of the pulses when Locking
and Unlocking the doors.
1.
Short pulse: The Door Lock & Unlock outputs will be
800mS in duration.
2.
Long pulse: The Door Lock & Unlock outputs will be a
3.5 seconds in duration.
8. Alarm Mode: Selects if the alarm functions are active or
bypassed.
1.
On: Alarm functions are operational as described
2.
Off: Alarm functions are NOT operational, but conve-
nience features and Remote Starter still operate
normally.
9. Auto Re-arming: Selects if the units will automatically Re-
arm/lock itself if alarm inputs 1 or 6 are not activated after trans-
mitter disarm/unlock.
1.
Off: The unit WILL NOT automatically Arm/Lock the
doors after transmitter Disarm/Unlock.
2.
On: The unit will automatically Arm/Lock the doors 120
seconds after transmitter Disarm/Unlock if Alarm Inputs
1 or 6 remain idle.
10. Alarm Chirps: Selects if the "Blue" Horn output wire will pulse
when Arm/Lock and Disarm/Unlock are activated.
1.
On: The Horn output will pulse 1 time for Arm/Lock and
2 times for Disarm/Unlock.
2.
Off: The Horn output WILL NOT pulse for Arm/Lock or
Disarm/Unlock.