To remove the component:
Power down the server blade (on page 13).
1.
Remove the server blade (on page 14).
2.
Place the server blade on a flat, level work surface with the bezel facing away from you.
3.
Extend the server B serial label pull tab.
4.
CAUTION:
Failure to use the jackscrews to remove and install the server B assembly can cause the system
boards to fail.
Turn jackscrew 1 approximately six turns counterclockwise.
5.
Turn jackscrew 2 counterclockwise until the threads are fully disengaged.
6.
Turn jackscrew 1 counterclockwise until the threads are fully disengaged.
7.
CAUTION:
connector.
Lift server B assembly from server A assembly, and then place it on the work surface with the system
8.
board facing up.

Install server B assembly

For access component identification, see "Access components (on page 11)."
Extend the server B serial label pull tab.
1.
Engage the front edge of server B assembly with the front edge of server A assembly.
2.
CAUTION:
the server B assembly is installed.
Lower server B assembly onto server A assembly.
3.
Align the signal and power connectors on server B assembly with the corresponding connectors on
4.
server A assembly.
The jackscrews control the unseating and seating of critical system connectors.
To prevent damage to the server blade, do not apply pressure to the enclosure
Route the cache module battery cables so that they do not become pinched when
Operations 15