Error Code
X X
(Hex.)
( AE
( AF
( B1
( B2
( B3
( B4
( B7
( B8
( BA
( BB
( BC
( BD
( BE
( BF
∗
( D
( E4
E6
( E8
( EA
( F5
( F6
( FF
Error codes in parentheses do not appear in the "MACHINE ERROR X X", since those errors are
displayed as messages described in "[ 1 ] Error messages on the LCD." In the maintenance mode
(Function code 82), those error codes may be displayed.
The CCD HP sensor sticks to OFF, indicating that the CCD unit has not
returned to the home position. )
The CCD HP sensor sticks to ON, indicating that the CCD unit has stayed in
the home position. )
Dark level offset data error. )
Gain control data error. )
Scan area left edge detection error. )
Scan area right edge detection error. )
A/D converter reference voltage error (at High level). )
A/D converter reference voltage error (at Low level). )
Magnification error for substantial white level data. )
Substantial white level data error in black & white mode. )
Substantial white level data error in photo mode. )
Black level data error. )
Detection error of black markings given on the white-level reference film. )
Detection error of ADF scanning position. )
Modem error. )
Out of recording paper. )
Write error in EEPROM.
Data scanning error during transmission. )
Document removed in phase B.)
EOL not found in page memory transmission mode. )
PC interface error. )
Fatal error. )
Error factor