both ends are available in 1, 5 and 10 m length. For cable
extension a Robnet2 T-Joiner is required.
When installing a system, try to minimize total Robnet2 cable
length by connecting all Robnet2 units to the nearest available
Robnet2 connector.
Total length of Robnet2 cable installed in a system should not
exceed 50 m (165').
Examples of interconnecting Robnet2 units:
AUTOPILOT
COMPUTER
A Robnet2 T-joiner P/N 24005662 is available to make the
Robnet2 interconnection more simple by reducing the number of
cables or extend cables when necessary.
See table for pin configuration and colour code of the network
cable.
The connectors are weather proof according to IP65, when
Note !
properly installed. All connectors not in use must be fitted with
the plastic cap to protect them against dirt and moisture.
78
CONTROL
UNIT
Figure 3-9 Interconnecting Robnet2 units
Cable pairs
Color code
Pink
1. pair
Grey
Brown
2. pair
White
Yellow
Figure 3-10 Robnet2 Connector
AP27
CONTROL
CONTROL
UNIT
UNIT
Signal
V SYSTEM+
V SYSTEM–
Bus–
Bus+
On - Off
COMPASS
JP27
20221495F