Temperature Measurements

The Meter measures the temperature of a type-K
thermocouple (included). Choose between degrees
Celsius ( C) or degrees Fahrenheit ( F) by pushing
C.
W Caution
To prevent possible damage to the Meter or
other equipment, use a thermocouple rated
for the temperatures to be measured. The
Meter is rated for -40.0 C to +400.0 C and
-40.0 F to 752 F, but the included type-K
thermocouple is rated to 260 C.
The temperature ranges are -40.0 C to +400 C and
-40.0 F to 752 F. All other temperatures show  on the
display. When there is no thermocouple connected, the
display shows .
To measure temperature:
1.
Connect a type-K thermocouple to the COM and 
terminals of the Meter.
2.
Turn the function switch to .
3.
Push C to choose Celsius or Fahrenheit.
True-rms Remote Display Digital Multimeter
How to Make Measurements

Continuity Tests

WCaution
To prevent possible damage to the Meter or
the equipment under test, disconnect power
and discharge all high-voltage capacitors
before a continuity test.
The continuity test uses a beeper that sounds when a
closed circuit is sensed. The beeper lets you do continuity
tests without the necessity to look at the display.
To do a continuity test, set up the Meter as shown in
Figure 3.