3.03 Top Outlet Concentric Flue Connection
3.03.1 Vertical concentric connection
Concentric
Vertical
Connector
3.03.2 Horizontal concentric connection
A 90° bend (fig. 16) is supplied for the horizontal connection of air and flue gas pipes. This can be oriented
towards the chosen wall in degrees of 45°.
L = S + D + 255
14
A vertical connector can be supplied for vertical
discharge with concentric pipes.
The simple mounting and use of double lip gaskets
at the joints makes this an extremely easy and safe
option.
For flue length up to 1 m long the 50 mmØ restrictor is
required. Longer than this no restrictor is required.
Fig. 15
Telescopic
30
Ø60
Ø80
95
190
270
Fig. 16
Ferroli F24
L
50*
125
70
D
S
70 min.
* = between 10 e 60 mm
-3 mm/m
80