Factory Reset; Power Up Quick Key Options - dbx DriveRack 260 User Manual

Complete equalization & loudspeaker management system
Hide thumbs Also See for DriveRack 260:
Table of Contents

Advertisement

Appendix A
A.1 Factory Reset
In the event that a reset is required, the DriveRack 260 offers you the option of performing a "Soft" or "Hard" reset. The
Soft Reset resets all operating parameters except user programs. The Hard Reset Procedure will reset all programmable
information back to the factory defaults.
All Power-Up Functions require a button(s) to be pressed and held as the unit power is turned on.
DriveRack 260 Power-Up Button Functions
Factory ("Hard") Reset.
Press and hold the <STORE> button at power-up until the following message appears:
• Pressing the <PREV PAGE> button will start a Factory Reset (All User Programs will become
copies of the Factory Programs, all Utility settings will be defaulted, and all Security settings
will be defaulted).
• Pressing the <PROGRAM> button will abort the Factory Reset sequence and the unit will
reset normally.
System ("SOFT") Reset
• Press and hold the <UTILITY> button at power-up until the following message appears:
• Pressing the <PREV PAGE> button will start a System Reset (All Utility settings will be defaulted.)
• Pressing the <PROGRAM> button will abort the System Reset sequence and the unit will
reset normally.
A.2 Power Up Quick Key Options
The DriveRack 260 offer several "Quick Key" options for initial power up and are as follow:
Change Initial Program Number
• To change the initial power program number, Press and hold the <PROGRAM> button at
power-up until the following message appears:
Use Wheel to"Change Restart"Program Number"
• Turning the <DATA> wheel will select the program you wish to load at initial reset.
• Press the <PROGRAM> button again when the selection is complete. Normal resetting will
continue.
System Lock Out
• Press and hold <RTA> at power-up until one of the following messages appears:
System Unlocked All user input will be accepted
System Locked No user input will be accepted
• Rotating the <DATA> wheel to select either Lock, Unlock or Filter Unlocked the system.
• Pressing <PREV PAGE> will unlock the system if it were locked or it will lock the system if it were unlocked.
• If you wish to leave the system locked with the exception of being able to clear the feedback filters, follow the same
procedure on power up and then rotate the <DATA> wheel to select the feedback filter unlock feature.
• Pressing any other button will abort the System Lockout sequence and the unit will reset normally.
66
DriveRack® User Manual
Appendix
"! HARD RESET?"
"Yes <PREV PAGE>"
"No <PROGRAM>"
"! SOFT RESET?"
"Yes <PREV PAGE>"
"No <PROGRAM>"
or