Section 5
10
1
46
DriveRack® User Manual
Utilities/Meters
The procedure for setting up the program list is as follows.
From Program mode, press the UTILITY button and use the PREV PG or NEXT PG
buttons to move to the page that appears something like this:
Program List
List Size
List Index
Program 1
Note that the arrow indicates the currently selected parameter for editing. To select
parameters to edit from the current page, press the DATA wheel until the arrow is next
to the parameter that you wish to edit.
With List Size selected, rotate the DATA wheel to set the list size. List Size is the total
number of programs that you need to select between; the selectable options are 1-10.
Once the list size has been selected, press the DATA wheel. Rotate the DATA wheel
to select Index 1, if it is not already selected. Press the DATA wheel in again to move
down to the program selection parameter. Rotate the DATA wheel to select the program
which you would like to appear first in your custom program list. Press the DATA wheel
twice to move back to the List Index parameter and rotate the DATA wheel to set this
to List Index number 2. Press the DATA wheel again, then rotate the DATA wheel to
select which program you would like to appear second in your custom program list.
Repeat this process for all programs which you want to appear in your custom program
list.
Once you are done creating your custom Program List you need to turn Program List
Mode on. To do this press the NEXT PG button. The display will appear something like
this:
Prog Change Mode
Program List
Prog Lock
Turn the DATA wheel to change the Program Change Mode from 'Normal' to 'Program
List'.
Once your program list has been built and Program Change Mode turned on, press the
PROGRAM/CONFIG button to exit.
Now as you turn the DATA wheel, you should see only the programs which you
assigned in your custom program list. If at any time you would like to set the Program
List Mode back to normal, simply press the UTILITY button, go back to the 'Prog
Change Mode' page and switch the mode from 'Program List' to 'Normal'.
Note: The Program Lock parameter shown in the above screen shot allows you to prevent
overwriting of certain User Programs. All program numbers from the set number and below will
be locked and cannot be overwritten.
DriveRack
Prog Change Mode
10
Program List
1
Prog Lock
Output Jumpers