HP StorageWorks 8/8 - SAN Switch Release Note page 48

Hp storageworks fabric os 6.2.0g release notes (5697-0355, march 2010)
Hide thumbs Also See for StorageWorks 8/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS 6.2.0d fixes
The following table lists defects closed in the Fabric OS 6.2.0d firmware release.
Table 12 Fabric OS 6.2.0d closed defects
Closed defect summary
Brocade 8–Gb SAN Switch for HP BladeSystem c-Class requires up-
dated serdes values for proper operation with 8–Gb mezzanine HBAs.
An out-of-memory condition can occur, leading to a switch panic due
to memory leak when an E_Port constantly goes on and off.
An out-of-memory condition can occur during hafailover/hare-
boot, leading to a switch panic due to memory leak when querying
connUnitPortFCId in Access Gateway mode, as well as when
querying FcFeModuleName.
On rare occasions, HP StorageWorks DC SAN Director may panic in
RTE module and hafailover during supportsave.
During HA recovery, Fabric Watch reports switch health as margin-
al/down on fully populated HP StorageWorks DC SAN Director. Traffic
is not impacted, but DCFM call home will not be initiated.
After HAfailover, SNMP v3 user configuration reverts back to default
values when configuring SNMP v3 user configuration on any one of
the user-defined USM configuration sets.
Detected termination of 0.weblinker.fcg on HP StorageWorks
DC04 SAN Director and messages like KSWD-1002, 5766, SLOT
4 | FFDC | CHASSIS, WARNING displayed on the console.
After enabling Virtual Fabric via DCFM on HP StorageWorks 8/40
SAN Switch, some ports may be disabled.
Missing FICON interrupt on HP StorageWorks DC04 SAN Director
due to CUP not responding in time before channel timed out.
Security commands such as fddcfg -fabwideset fail with RCS
transaction error.
When performing firmwareupgrade from Fabric OS 6.1x to 6.2.0
then reverting back to 6.1.x via firmwarerestore, the downgrade
fails and leaves the CP with unrecoverable passwords, leaving it in
an inconsistent state where the user may not be able to login.
Disconnecting/reconnecting an ISL on the HP StorageWorks Encryption
SAN Switch while a rekey operation is in progress may result in failure
of new key creation. LUN state shows Rekey ACK timeout.
48
Solution
Updated serdes values are provided
in Fabric OS 6.2.0d.
Fixed in Fabric OS 6.2.0d
Workaround prior to upgrade: Avoid
querying FcFeModuleName or
connUnitPortFCId in AG mode.
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d
Workaround prior to upgrade: Once
passwords are blocked, boot into
single user mode and reset system
passwords.
Fixed in Fabric OS 6.2.0d
Fixed in Fabric OS 6.2.0d

Hide quick links: