XRC Emulation allows FICON Disk Control Unit paths to be activated
with DPR Mode.
FMS stuck busy condition caused host *MASTER* START PENDING
upon bringing switch online to mainframe operating system.
CP card of HP StorageWorks 4/256 SAN Director is set to FAULTY
(51).
HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches: when
normal fan activity is interrupted, the high RPM fan rate cycle time
takes 1 hour.
RLS request from FICON host receives LS_RJT 031F in Interopmode 2.
FMS Mode enable failed due to insufficient frame filtering resources
on some ports.
HP StorageWorks DC SAN Backbone Director blades fault after reset-
ting a server with 32 HBAs.
Fast Write configuration not properly installed after repeated, back-to-
back cable pull and re-inserts.
Out of Order frames delivered to HP StorageWorks DC SAN Backbone
Director via FICON channel from HP StorageWorks 8/40 SAN Switch
attached to a storage device (DASD).
CAL exception "Non-Secure tunnel can not be configured on the same
port as IP sec enabled tunnels." come when trying to configure an IP
Sec tunnel on a switch which already had Non secure tunnels in it.
Fast Write will attempt to configure, even on an HP StorageWorks B-
series Multi-protocol Router blade that has failed to initialize success-
fully.
Zoned crashes after HP StorageWorks DC SAN Backbone Director
power cycle and zone transaction aborted
SMIA does not have information about SFP/GBIC type for a port.
The tag field of the node identifier command returned contains the port
number on which the command was received, instead of the tag field
of the device on the other end of the link.
Gzoneinfo.htm is returning empty zone information on fabric with
Fabric OS 6.1.1.
Kernel Panic on 8Gb SAN Switch for HP BladeSystem c-Class after
firmwaredownload.
42
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Power cycle the slot. Set port speed
to anything other than autonegotiate.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The embedded platforms have well
known user/server ports documented
in the user manuals.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Fixed in Fabric OS 6.2.0.