N_Port between AG and Edge Switch (300) may become stuck at
E_Port Unknown state.
After multiple successive fastboots of an HP StorageWorks DC04 SAN
Director, there was a panic due to the zone daemon dying.
FICON PTP VTS Selective Resets and Aborted sequences caused by
incorrect entry into FICON tape read pipelining.
EX_Port fails to come online after downgrading firmware from Fabric
OS 6.x to 5.3 under certain conditions.
Tstimezone settings cannot be changed or restored with config-
download.
If a large number of EX_Ports are enabled at the same time, occasion-
ally some fail due to incompatible flow control parameters.
In some instances, portshow may display inaccurate port authentic-
ation description or state after a CP failover.
Internal server ports on embedded platform: traffic may stop due to
loss of buffer credit.
The error message is cryptic when the interop fabric contains more
than 60 devices in the default zone and the user tries cfgenablecfg-
disable.
When disabling/enabling a port, port fencing disables the port be-
cause the allowable number of invalid transmission words is exceeded.
Ag --show on an HP StorageWorks 8/8 or 8/24 SAN Switch shows
incorrect edge switch IP address after a slave port is swapped with
an N-port outside of the trunk group.
The 32-character switchname and chassisname extensions do not fully
display in RASLog outputs, such as errdump or supportsave output.
FFDC occurs when 16-31 char switch/chassis name is input on a
platform that only supports up to 15.
I2C response failure and subsequent reset occasionally results in HP
StorageWorks DC SAN Backbone Director fan fault errors.
36
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable and then enable the port on
the AG to bring the port back online
as an N-Port.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Fastboot a single time.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Remove the ts.tz parameter in the
config file and then download.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Portdisable and then enable the
EX_Ports that failed.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch and ag --show
cli will show the correct output.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use only 16-character switchname
and chassisname fields if full name
display in the logs is required.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.