HP StorageWorks 8/8 - SAN Switch Release Note page 40

Hp storageworks fabric os 6.2.0g release notes (5697-0355, march 2010)
Hide thumbs Also See for StorageWorks 8/8 - SAN Switch:
Table of Contents

Advertisement

Hareboot on 400 MP Router FC Fast Write enabled switch causes
the system to panic with Oops: kernel access of bad area,
sig: 11 [#1].
Fabric Mode TT displays redundant flows with different values for the
same SID/DID pair on the core switches when there are redundant
trunk groups to the same edge domain.
DLS ON does not rebalance when ISLs to a different switch are re-
moved on HP StorageWorks DC SAN Backbone Director and HP
StorageWorks 8/80 SAN Switch.
On an HP StorageWorks 8/80 SAN Switch, the system status LED
does not flash amber/green when a power supply is faulted.
User with admin role in some AD is able to add another user with
admin role in AD as ALL.
Reset to default button is grayed out always in SCSI vs. IP traffic setup
window.
USB Admin is not in sync with CLI when launched . It shows the correct
info only when we click refresh button.
Name Server database is being set with incorrect WWN's for NPIV
nodes when port ALPA = 0x13.
Potential timeouts and aborts during Device Discovery and CU busy
processing when using FICON XRC Emulation.
When an HP StorageWorks DC SAN Backbone Director blade is
powered off, Fabric Watch displays unnecessary warning message
about SFP voltages.
The EnumerateSelectedInstances CAL call returns a port that
is not present in GFABRIC MS call.
FICON Tape Write Pipelining does not function with converter.
In configure tab under switch admin tab, if value entered in R_A_TOV
and E_D_TOV is more than the threshold, the error message displays
the wrong range of values to be entered.
Integrated Routing with multiple ports in an EX_Port trunk, may not
properly send an entire exchange on the same link.
Sort does not work on Accessible Devices screen of name server.
40
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Perform switchdisable and
switchenable to force a rebalance
of the routes.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port ALPA must be set to default value
of 0x00 for ports hosting NPIV nodes.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Ignore messages; they indicate no
problem and have no side effect.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable trunking on HP StorageWorks
DC SAN Backbone Director and HP
StorageWorks 8/8, 8/24, 8/40,
and 8/80 SAN switches EX_Ports.
Fixed in Fabric OS 6.2.0.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents