In rare instances the Name Server DB is out of sync between FOS and
EOS switches in interop mode 3.
Seccertutil show does not display the contents of certificates with
.cer extension.
When resetting all the hosts on a blade or slotpoweroff on a blade,
HP StorageWorks 4/256 SAN Director CP reboots due to the Software
Watchdog detecting unexpected termination of the Name Server
daemon.
Fastboot causes unnecessary FFDC, ERROR, ..., libipadm:
em_AdmSwitchNameGet()
In some instances of congestion in the Ethernet network, the displayed
VE port utilization value is incorrect.
Reject code '0B' response to a QSA frame causes channel definition
errors.
When the switch name is set using CLI and then read using the Read
Port Address Name x'B2' command to the CUP Port x'FE' it returns the
switch name with a x'7F' attach after the last character in the Switch
Name.
A failed Pause frame (sent during firmwaredownload process in
Interop Modes 2 and 3), causes a fabric rebuild.
In some instances, HCL on an HP StorageWorks 8/40 SAN switch in
Interop Mode requires the use of the -o option.
A turboramtest failure does not fully disable the port on an HP
StorageWorks 8/80 SAN switch.
Web Tools: The HP StorageWorks DC04 SAN Director attention LEDs
on the switch view GUI window do not turn amber when blade needs
attention.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
After locating the device ID, disable
and then enable that device.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Only LDAP certificates with .cer ex-
tension is supported; so use the
--ldapcert option for importing
.cer certificates.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use portperfshow command.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Block off a badly misbehaving port
that is generating bad traffic on a
switch port that is putting a lot of
stress on the embedded port.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option to override the co-
operative HCL feature.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0g release notes