Conversion of uwatt to dbm for GE ports Tx Rx values shown in Web
Tools are incorrect.
HP StorageWorks 8/40 SAN Switch: FRU faulty status is not recovered
correctly.
Third-party array responds to ADISC with LOGO only over router
fabric, S_ID does not match N_ID.
Ipfilter – Audit log (SEC- 3035, 3036, 3037): message properties
generating log without the appropriate key word.
AG trunks are not formed correctly when connected to an embedded
switch.
Tape Selective Reset error due to incorrect handling of Early End Syn-
chronization status.
F_Port prefers to multiple N_Ports
FICON Device Level Ack Emulation Processing error.
Command ipaddrshow does not show the IP address of a blade that
is seated in slot 12 of an HP StorageWorks DC SAN Backbone Direct-
or.
Re-key of LUNs hosted through active/passive ports will not complete
if started on the passive path.
Wave Length column in port optics dialog is currently blank.
Host may lose targets on edge AG in cascaded setup when failover
from core-AG to another core-AG connected to different edge fabric
switches.
Web Tools zoning breaks when third-party storage virtualization ap-
pliance changed to standby mode.
The removal of an encryption performance upgrade license is not
prevented.
After configuring HP StorageWorks 8/8 or 8/24 SAN Switch AG so
that F_Port Trunking works and then performing portdisable on N-
Ports and then hareboot the 8/8 or 8/24 SAN Switch AG caused
unexpected termination of AGD
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Turn on the power switch as soon as
possible after inserting a fan/power
supply unit into the system.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
For McDATA mode edge fabric, only
McDATA switches have to be connec-
ted directly to FCR. The work around
is valid as long as we have only
McDATA switches directly connected
to Ex-Ports.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Issue ipaddrshow -slot 12 to get
the information.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable/enable the N_Port.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Change the third-party storage virtual-
ization appliance to standby cf mode.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0g release notes