Seccertutil gencsr is not accepted in non-interactive mode if
parameter has a space in it.
IPAD FFDC error occurred after reboot of HP StorageWorks 4/8 or
4/16 SAN Switch.
HP StorageWorks 8/80 SAN Switch licenses disappeared and user
is not able to re-install them.
Switch Throughput Utilization Graph launches with all ports in graph
if we try launching by removing all ports from the edit Switch
Throughput Utilization dialog.
CUP Asynchronous Error Reporting Location not being set by default.
AG N_Port connected to embedded switch in interopmode 2 could
not restart traffic after switchdisable/enable followed by con-
figupload/download.
All ports come up Disabled (Persistent) after FMS mode is set while
switch is offline.
Fast Write could obtain incorrect FCP command data length if the
optional additional CDB length is selected.
Security Violation Console Message reported on nonexistent port# on
an HP StorageWorks 4/64 SAN Switch (interopmode 2) with no se-
curity policy set.
Fabric OS does not send RSCN for CUP disable / enable in NI
mode 2.
Channel ack_1 to Control Unit ACC is being F_RJT'd after successful
RNID.
F_RJT not returned for unroutable class 2 PLOGI.
Missing CE DE status.
FMS does not retry status after FICON channel returns LBY for Device
End.
FICON CUP reports incorrect Director Size Code in Basic Sense and
Sense ID data for HP StorageWorks 8/40 and 8/80 SAN switches.
Portcfgspeed command on 8G FC platforms are accepting invalid
port speed = 5.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the interactive mode to generate
the csr file.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Clean install.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do not use port 0 for an ISL.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do not provide a value of 5 to the
portcfgspeed command. Speed
will be set to 8. If that is not desired,
re-submit the command with the
proper port speed.