Optimum Environment; Space And Airflow Requirements - HP ML310 - ProLiant - G2 User Manual

Generation 2 server
Hide thumbs Also See for ML310 - ProLiant - G2:
Table of Contents

Advertisement

If you intend to deploy and configure multiple servers in a single rack, refer to
the white paper on high-density deployment on the HP website
(http://www.hp.com/products/servers/platforms).

Optimum Environment

When installing the server, select a location that meets the environmental
standards described in this section.

Space and Airflow Requirements

Tower Server
In a tower configuration, leave at least a 7.6-cm (3-in) clearance space at the
front and back of the server for proper ventilation.
Rack Server
To allow for servicing and adequate airflow, observe the following space and
airflow requirements when deciding where to install a rack:
HP servers draw in cool air through the front and expel warm air through the
rear. Therefore, the front and rear rack doors must be adequately ventilated to
allow ambient room air to enter, and allow the warm air to escape from the
cabinet.
Coupling multiple racks
The Rack Products Documentation CD enables you to view, search, and print
documentation for HP and Compaq branded racks and rack options. It also
helps you set up and optimize a rack in a manner that best fits your
environment.
Leave a minimum clearance of 76.2 cm (30 in) in front of the rack.
Leave a minimum clearance of 76.2 cm (30 in) behind the rack.
Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to
the back of another rack or row of racks.
Server Setup
27

Advertisement

Table of Contents
loading

Table of Contents