NOTE: If the hot-plug power supply is being installed or replaced in power supply bay 1,
and the sliding rail solution has been installed, remove the cable retractor from the fixed
rack rail by loosening the cable retractor thumbscrew and pushing the cable retractor back
away from the server chassis and then out away from the rack rail.
2. Slide the redundant power supply into the power supply bay until it snaps into
place.
Figure 2-19: Installing the hot-plug redundant power
supply

Hot-Plug DC Power Supply Wiring Setup

If a hot-plug DC power supply has been installed, verify the following:
1. Be sure that the free end of the DC power cord is connected to a PDU or other
suitable DC power source.
IMPORTANT: If the power supply fails to operate, the blue and black wires may be connected
incorrectly. When connected properly, the black wire should be at a higher potential (more
positive) relative to the blue wire. The power supply features reverse polarity protection so that
no damage occurs if the power supply is connected incorrectly.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide