Pressure Relief Procedure - Graco 390 Electric Airless Sprayer Important Safety Instructions Manual

Electric airless sprayer
Table of Contents

Advertisement

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you
are instructed to relieve pressure, stop spraying, check
or service equipment or install or clean spray tip.
1. Turn OFF power and turn pressure control to lowest
pressure setting.
2. Hold gun against side of grounded metal flushing
pail. Trigger gun to relieve pressure.
ti8324 c
8
ti5310c
3. Turn prime valve down.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
4. Engage trigger safety lock on gun if unit is being
shut down or left unattended.
Pressure Relief Procedure
ti8326a
311737B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents