3.6.1 SIP Settings
3.6.1.1 SIP Setting
SIP User Agent
Description
Value Range
Default Value
Configuration File Reference
3.6.1.2 Transport Protocol for SIP
Transport Protocol
Description
Value Range
Default Value
Configuration File Reference
84
Administrator Guide
Specifies the text string to send as the user agent in the headers of SIP
messages.
Max. 40 characters
Note
•
You cannot leave this field empty.
•
If "{mac}" is included in this field, it will be replaced with the
unit's MAC address in lower-case.
•
If "{MAC}" is included in this field, it will be replaced with the
unit's MAC address in upper-case.
•
If "{MODEL}" is included in this field, it will be replaced with the
unit's model name.
•
If "{fwver}" is included in this field, it will be replaced with the
firmware version of the unit.
Panasonic_{MODEL}/{fwver} ({mac})
SIP_USER_AGENT (Page 180)
Selects which transport layer protocol to use for sending SIP packets.
Note
•
If you change this setting, the unit will restart automatically once
the message "Complete" appears. If the unit is on a call, it will
restart after it returns to idle.
•
UDP
•
TCP
UDP
SIP_TRANSPORT_[1–8] (Page 195)
Document Version