Lacp Configuration - HP 438031-B21 - 1:10Gb Ethernet BL-c Switch Reference Manual

Hp 1:10gb ethernet bl-c switch for c-class bladesystem browser-based interface reference guide
Hide thumbs Also See for 438031-B21 - 1:10Gb Ethernet BL-c Switch:
Table of Contents

Advertisement

LACP Configuration

To display the following form, select Layer 2 > LACP.
The following table describes the Switch LACP Configuration controls:
Switch LACP Configuration controls
Table 124
Control
LACP System Priority (1-65535)
Timeout time
Description
Defines the priority value (1 through 65535) for the switch. Lower numbers
provide higher priority. The default value is 32768.
Defines the timeout period before invalidating LACP data from a remote
partner. Choose short (3 seconds) or long (90 seconds). The default value is
long.
HP recommends that you use a timeout value of long, to reduce
NOTE:
LACPDU processing. If your switch's CPU utilization rate remains at 100% for
periods of 90 seconds or more, consider using static trunks instead of LACP.
Configuring the switch
183

Advertisement

Table of Contents
loading

This manual is also suitable for:

1:10gbe

Table of Contents