Installation instructions

Electrical installation

WARNING!
The receptacle on the rear of the machine is
designed to accommodate ASKO cleaning
machines ONLY (rated 208–240 V.) To use this
receptacle, you must use the ready-fitted plug
supplied with the cleaning machine or an
equivalent.
ASKO cleaning machines rated 208–240 V have
two internal fuses of 15 A each.
The machine should only be connected to a
grounded wall socket.
WARNING!
This appliance must be properly grounded. Refer
to the "Important Safety Instructions" for
grounding instructions.
The power supply cord must be grounded. If the
machine is to be used in a wet area, the supply
must be protected by a residual current device.
Connection to a permanently wired supply point
must be made only by a qualified electrician. As
supplied: Single-phase, 208-240 V, 60 Hz,
3000W heater rating 30 A circuit required
Remove cover to
access terminal box.
(Requires a 20-Torx
screwdriver.)
Electrical Connections
WARNING!
Read the Electrical requirements and grounding
instructions before connecting the tumble dryer.
Electric models of the dryer are manufactured for
a 3-wire connection system. The dryer frame is
grounded by a link to the neutral conductor on the
dryer terminal block. If local codes do not permit
grounding through the neutral, the grounding link
from the terminal block must be removed and a
separate ground wire must be used.
Only a 4-conductor cord shall be used when the
applience is installed in a location where
grounding through the neutral conductor i
prohibited. Grounding through the neutral
conductor is prohibited for new branch-circuit
installations, mobile homes, recreational vehicles,
and areas where local codes prohibit grounding
through the neutral condutors. The grounding link
on the dryer must be removed for all 4-wire
installations.
These Electrical Connection instructions provide
for installing the dryer in the following situations:
3-wire connection where local codes permit
grounding through the neutral. 3-wire connection
plus separate grounding connector where local
codes do not permit grounding through the
neutral.
4-wire connection.
Each of the above connections can be made with
an approved power supply cord or by direct wiring.
Each connection instruction identifies the
appropriate Power Supply Cord and covers
requirements for direct wiring.
NOTE!
In Canada, the dryer is delivered ready-fitted
with a four-prong plug intended for connection
to a single-phase supply.
Customer Care Center
1-800-898-1879
www.askousa.com