Installation instructions

Air exhaust

Connecting the exhaust duct to the dryer
NOTE!
You will need to purchase a UL-CSA-approved
4-inch ridged metal exhaust duct. The dryer is
delivered with the stub pipeattached to the rear
exhaust outlet, but the exhaust duct can be
attached to either the right or left exhaust outlet.
Asko dryers have a
"T-stile" exhaust vent that
allows you to connect the
duct on the rear or on the
left or right side
.
Side Exhaust Outlet
The duct must not be assembled with screws or
other fastenings that extend into the duct and
trap lint.
20
Vent
T-tube
Rear Exhaust Outlet
Stub
Duct
Clamp
(not supplied)
Customer Care Center
1-800-898-1879
www.askousa.com
To connect the exhaust duct to the rear
outlet
To connect the exhaust duct to the rear outlet,
follow the steps below:.
1. Push the duct onto the stub pipe and secure it
with a clamp
2. With the duct attached, insert the stub pipe into
the hole. It should snap into place.
3. After you push the dryer into place, check for
kinks in the duct.
NOTE!
Excessive duct length and too many bends can
impede drying performance. We recommend
that you cut off any excess exhaust duct and run
the duct with as few bends as possible. Make
any necessary bends as gentle as possible.
NOTE!
Maximum duct length of 60 feet and 4 elbows is
allowed. Subtract 4 feet of duct for each 90°
elbow.