A.O. Smith SGE Installation And Operation Manual page 82

A.o. smith condensing gas - solar water heater installation manual
Table of Contents

Advertisement

Code + Description
Cause
S08 (blocking error)
Sensor is not (correctly)
connected
Open circuit from
temperature sensor S1
Damaged cable or
in the collector
defective sensor
S11 (blocking error)
Short circuit in sensor
circuit
Short circuit in the
temp. sensor T2 at the
bottom of the tank
S12 (blocking error)
Short circuit in sensor
circuit
Short circuit in sensor 1
of temperature sensor
T
at the top of the
1
(1)
tank
S13 (blocking error)
Short circuit in sensor
circuit
Short circuit in sensor 2
of temperature sensor
T1 at the top of the
(1)
tank
S14 (blocking error)
Short circuit in sensor
circuit
Short circuit from
dummy 1
S15 (blocking error)
Short circuit in sensor
circuit
Short circuit from
dummy 2
S17 (blocking error)
Sensor is not (correctly)
connected
Short circuit in temp.
sensor S1 at bottom of
tank
Instruction manual SGE
Solution
Connect the sensor lead to J13 (port 2 and 4) of the solar controller See the SGE electrical diagram
Replace the sensor
Replace sensor T
2
Replace sensor T
1
Replace sensor T
1
(2)
Replace the dummy sensor
(2)
Replace the dummy sensor
Replace sensor S2
Remark
(17 "Appendices")
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
To replace the necessary parts, you must contact your installation
engineer
is
82

Advertisement

Table of Contents
loading

This manual is also suitable for: