  • Page 1 Voorraadvat Storage tank Ballons de stockage ST - 300 Installatie-, Gebruikers- en Servicehandleiding Installation, User and Service Manual Notice d’installation, Mode d’emploi, Notice d’entretien Innovation has a name.
  • Page 2 Uw Installateur / Your Installer / votre installateur A.O. Smith Hoofdkantoor Europa, De Run 5305, 5503 LW Veldhoven www.aosmith.nl, 0800-AOSMITH (2676484) A.O. Smith UK, Unit B8 Amstrong Mall, Southwood Business Park, Farnborough, Hampshire GU14 0NR www.aosmith.co.uk A.O. Smith France, 14, allée Charles Pathé, 18000 Bourges...
  • Page 3 ST 300 Inhoudsopgave / Table of contents / Table des matières Deze handleiding bestaat uit 3 talen. 1 - NL Handleiding ST 300 ....................5 2 - UK Manual ST 300 ......................21 3 - FR Notice ST 300 ......................37 This manual consists of 3 languages.
  • Page 4 ST 300...
  • Page 5 A.O. Smith Water Products Company. A.O. Smith Water Products Company behoudt zich het recht voor de specificaties zoals vermeld in deze handleiding te wijzigen.
  • Page 6 ST 300 Installatie-, Service- en Gebruikershandleiding...
  • Page 7: Table Of Contents

    Waterzijdig onderhoud .................... 17 Garantie ......................... 19 Garantie algemeen ....................19 Garantie tank ......................19 Voorwaarden installatie en gebruik ................. 19 Uitsluitingen ......................20 Omvang garantie ....................20 Claims ........................20 Verplichtingen voor A.O. Smith ................20 Installatie-, Service- en Gebruikershandleiding...
  • Page 8 ST 300 Installatie-, Service- en Gebruikershandleiding...
  • Page 9: Technische Specificaties

    ST 300 Technische specificaties 1.1 Vloerbelasting Houd in verband met het gewicht van het toestel rekening met de maximale vloerbelasting, zie de tabel (1.6 "Algemene gegevens"). 1.2 Watersamenstelling Het toestel is bedoeld om drinkwater op te warmen. Het drinkwater moet voldoen aan de regelgeving voor drinkwater voor menselijke consumptie.
  • Page 10: Algemene Gegevens

    ST 300 1.6 Algemene gegevens Algemene gegevens Eenheid ST 300 Inhoud ltr. Ledig gewicht Maximale vloerbelasting Energie-efficiëntieklasse (Energie Label) Stilstandsverlies Maximale werkdruk kPa (bar) 1000 (10) Maximale temperatuur ºC Anodes 1.7 Afmetingen Afmetingen Eenheid ST 300 Totale hoogte 1650 Diameter Hoogte koudwatertoevoer Hoogte warmwateruitlaat 1460...
  • Page 11 ST 300 Vooraanzicht doorsnede toestel IMD-1281 R0 Installatie-, Service- en Gebruikershandleiding...
  • Page 12 ST 300 Installatie-, Service- en Gebruikershandleiding...
  • Page 13: Installatie

    ST 300 Installatie 2.1 Aansluitschema De figuur geeft het aansluitschema weer. Dit schema wordt gebruikt in de paragrafen waarin het eigenlijke aansluiten wordt beschreven. Installatie Schema Legenda 2. inlaatcombinatie (verplicht) 3. T&P-ventiel (aanbevolen) 4. afsluiter (aanbevolen) 5. terugslagklep (verplicht) 6. circulatiepomp (optioneel) A.
  • Page 14 ST 300 Let op Een inlaatcombinatie is verplicht. Monteer deze zo dicht mogelijk bij het toestel. Waarschuwing Tussen inlaatcombinatie en het toestel mag nooit een afsluiter of terugslagklep geplaatst worden. 2.2.2 Warmwaterzijdig Zie (B) in het aansluitschema (2.1 "Aansluitschema"). Opmerking Isolatie van lange warmwaterleidingen voorkomt onnodig energieverlies.
  • Page 15: Vullen En Aftappen

    ST 300 Vullen en aftappen Installatie Schema Legenda 2. inlaatcombinatie (verplicht) 3. T&P-ventiel (aanbevolen) 4. afsluiter (aanbevolen) 5. terugslagklep (verplicht) 6. circulatiepomp (optioneel) A. koudwatertoevoer B. warmwaterafvoer C. circulatieleiding IMD-1284 R0 3.1 Vullen Om het toestel te vullen gaat u als volgt te werk: 1.
  • Page 16: Aftappen

    ST 300 3.2 Aftappen 1. Sluit de afsluiter in de warmwaterleiding. 2. Sluit de toevoerkraan van de inlaatcombinatie (2). 3. Open de aftapkraan. 4. Belucht het toestel (of installatie) zodat het helemaal kan leeglopen. Installatie-, Service- en Gebruikershandleiding...
  • Page 17: Onderhoud

    ST 300 Onderhoud Let op Onderhoud mag alleen door een erkend service- en onderhoudsmonteur worden uitgevoerd. Bij elke onderhoudsbeurt dient het voorraadvat waterzijdig onderhouden te worden. Het onderhoud dient in de volgende volgorde te worden uitgevoerd. 1. Onderhoud voorbereiden 2. Waterzijdig onderhoud 3.
  • Page 18 ST 300 Werkvolgorde: 1. Draai de bouten van de reiningsopening los. 2. Verwijder de deksel en de pakking. 3. Inspecteer de tank en verwijder de losse kalkaanslag en verontreinigingen. 4. Indien de kalkaanslag niet handmatig verwijderd kan worden, dient ontkalkt te worden met een ontkalkingmiddel.
  • Page 19: Garantie

    Indien binnen één jaar na de oorspronkelijke installatiedatum van een door A.O. Smith geleverd voorraadvat, na onderzoek en ter uitsluitende beoordeling van A.O. Smith, blijkt dat een deel of onderdeel, met uitzondering van de tank, niet of niet juist functioneert ten gevolge van fabricage- en/of materiaalfouten, zal A.O. Smith dit deel of onderdeel vervangen of repareren.
  • Page 20: Uitsluitingen

    5.5 Omvang garantie De verplichtingen van A.O. Smith krachtens de gegeven garantie gaat niet verder dan kosteloze levering af magazijn van de te vervangen delen of onderdelen respectievelijk voorraadvat. vervoers-, arbeids-, installatie- en andere met de vervanging verband houdende kosten komen niet voor rekening van A.O.
  • Page 21 Any brand names mentioned in this manual are registered trademarks of their Trademarks respective owners. A.O. Smith Water Products Company accepts no liability for claims from third parties Liability arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
  • Page 22 ST 300 Installation, Service and User Manual...
  • Page 23 Warranty ........................ 35 General warranty ....................35 Tank warranty ......................35 Conditions for installation and use ................35 Exclusions ....................... 36 Scope of warranty ....................36 Claims ........................36 Obligations of A.O. Smith ..................36 Installation, Service and User Manual...
  • Page 24 ST 300 Installation, Service and User Manual...
  • Page 25: Technical Specifications

    ST 300 Technical specifications 1.1 Floor load Allow for the storage tank's weight and the maximum floor load; refer to the table (1.6 "General specifications"). 1.2 Water composition The storage tank is intended for storage of drinking water. The drinking water must comply with the regulations governing drinking water for human consumption.
  • Page 26: General Specifications

    ST 300 1.6 General specifications General specifications Unit ST 300 Contents litres Empty weight Maximum floor load Energy Efficiency Class (Energy Label) Heat Loss Maximum operating pressure kPa (bar) 1000 (10) Maximum water temperature ºC Anodes 1.7 Dimensions Dimensions Unit ST 300 Total height 1650...
  • Page 27 ST 300 Front sectional view of the appliance IMD-1281 R0 Installation, Service and User Manual...
  • Page 28 ST 300 Installation, Service and User Manual...
  • Page 29: Installation

    ST 300 Installation 2.1 Installation diagram This figure shows the installation diagram. This diagram is referred to in the sections describing the actual connection procedure. Installation Diagram Legend 1. pressure relief valve (mandatory if mains water pressure is too high) 3.
  • Page 30 ST 300 Hot Water side 2.2.2 See (B) in the installation diagram (2.1 "Installation diagram"). Note Insulating long hot water pipes prevents unnecessary energy loss. 1. Optional: fit a temperature gauge (12) so you can check the temperature of the tap water.
  • Page 31: Filling And Draining

    ST 300 Filling and draining Installation Diagram Legend 1. pressure relief valve (mandatory if mains water pressure is too high) 3. T&P-valve 4. stop valve (recommended) 5. non-return valve (mandatory) 6. circulation pump (optional) 9. drain valve 11. service stop valve 12.
  • Page 32: Draining

    ST 300 3.2 Draining 1. Close the stop valve (4) between the cold water head tank and the cold water inlet (A). 2. Open the drain valve (9). 3. Bleed the water heater (or installation) so that it drains completely. Installation, Service and User Manual...
  • Page 33: Maintenance

    ST 300 Maintenance Warning Maintenance may only be carried out by a competent person. At each service, the storage tank undergoes maintenance on water side. The maintenance must be carried out in the following order. 1. Preparation for maintenance 2. Water-side maintenance 3.
  • Page 34 ST 300 Work order: 1. Undo bolts from the cover. 2. Remove cover and the gasket. 3. Inspect the tank and remove the loose scale deposits and contamination. 4. If the scale cannot be removed by hand, descale the storage tank with a descaling agent.
  • Page 35: Warranty

    A.O. Smith shall offer to replace the defective storage tank with an entirely new storage tank of equivalent size and quality. The warranty period given on the replacement storage tank shall be equal to the remaining warranty period of the original storage tank that was supplied.
  • Page 36: Exclusions

    (assemblies or parts of) storage tanks supplied for replacement, other than the warranty expressly set out in this Certificate. Under the terms of the supplied warranty, A.O. Smith is not liable for damage to persons or property caused by (assemblies or parts, or the glass-lined steel tank of) a (replacement) storage tank that it has supplied.
  • Page 37 écrit préalable de A.O. Smith Water Products Company. A.O. Smith Water Products Company se réserve le droit de modifier les spécifications de ce manuel d'instructions. Toutes les marques mentionnées dans ce manuel d'instructions sont des marques Marques de commerce déposées par les fournisseurs concernés.
  • Page 38 ST 300 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 39 Garantie générale ....................51 Garantie sur la cuve ....................51 Conditions d'installation et d'utilisation ..............51 Exclusions ....................... 52 Portée de la garantie ....................52 Réclamations ......................52 Obligations de A.O. Smith ..................52 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 40 ST 300 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 41: Spécifications Techniques

    ST 300 Spécifications techniques 1.1 Charge maximale au Tenez compte de la charge maximale exercée sur le sol par le poids de l'appareil, sol de l'appareil voir le tableau (1.6 "Données générales"). 1.2 Composition de l'eau L'appareil est destiné à réchauffer de l'eau potable. L'eau potable doit être conforme aux régulations d'eau potable pour la consommation humaine.
  • Page 42: Données Générales

    ST 300 1.6 Données générales Données générales Unité ST 300 Capacité Poids à vide Charge maximale au sol de l'appareil Class Efficacité Énergétique (Étiquette d’Énergie) Consommation d’entretien Pression de fonctionnement max. du cuve kPa (bar) 1000 (10) Température maximale du cuve ºC Nombre d'anodes 1.7 Dimensions...
  • Page 43 ST 300 Vue de frontale des appareils IMD-1281 R0 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 44 ST 300 Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 45: Installation

    ST 300 Installation 2.1 Schéma de raccor- Cette illustration représente le schéma de raccordement. Ce schéma est utilisé dans dement les paragraphes suivants contenant une description du raccordement proprement dit. Schéma de raccordement Légende 2. groupe de sécurité (obligatoire) 3. soupape thermique (recommandée) 4.
  • Page 46 ST 300 Attention Un groupe de sécurité est obligatoire. Montez-le le plus près possible de l'appareil. Avertissement Entre la combinaison d'entrée et l'appareil, vous ne pouvez jamais monter de vanne d'arrêt ou de clapet anti-retour. Côte eau chaude 2.2.2 Voir (B) du schéma de raccordement (2.1 "Schéma de raccordement"). Note L'installation des longues conduites d'eau chaude évite les pertes énergétiques inutiles...
  • Page 47: Remplissage É Vidange

    ST 300 Remplissage é Vidange Schéma de raccordement Légende 2. groupe de sécurité (obligatoire) 3. soupape thermique (recommandée) 4. vanne d’arrêt (recommandée) 5. clapet anti-retour (obligatoire) 6. circulateur de bouclage (option) A. alimentation en eau froide B. sortie d’eau chaude C.
  • Page 48 ST 300 3.2 Vidange Fermez la vanne d'arrêt dans la conduite d'eau chaude. 1. Fermez le robinet d'arrivée du groupe de sécurité (2). 2. Ouvrez le robinet de vidange. 3. Purgez l'appareil (ou l'installation) pour qu'il (elle) puisse se vider complètement. Notice d’installation, Mode d’emploi, Notice d’entretien...
  • Page 49: Effecteur L'entretien

    ST 300 Effecteur l'entretien Attention L'entretien ne peut entré effectué que par un professionnel de la maintenance ou de l'entretien agréé. A chaque entretien, l'appareil doit être contrôlé côté eau et côté gaz. L'entretien doit s'effectuer dans l'ordre suivant. 1. Préparer l'entretien 2.
  • Page 50 ST 300 Ordre du travail : 1. Faites tourner les boulons de l’ouverture de nettoyage. 2. Éliminez le couvercle et le joint. 3. Inspectez le réservoir. Éliminez la couche de calcaire accumulée et les saletés. 4. Si la couche de calcaire ne peut être éliminée manuellement, il convient de retirer le calcaire avec un détartrant.
  • Page 51: Garantie

    Si, moins de trois ans après la date initiale de l'installation d'un chauffe-eau livré par cuve A.O. Smith, après examen par et sur l'appréciation exclusive de A.O. Smith, la cuve en acier thermo vitrifié présente des fuites suite à une formation de rouille ou de corrosion du côté...
  • Page 52: Exclusions

    5.5 Portée de la garantie Les obligations de A.O. Smith conformes à la garantie accordée se limite à la livraison gratuite de l'entrepôt des pièces ou parties à remplacer ou de l'appareil à...