Trfc3 for DIMM4
Options are: Auto (default), 90ns, 110ns, 160ns, 300ns, 350ns.
Write Recovery Time
Options are: Auto (default), 5T~8T, 10T, 12T.
Precharge Time
Options are: Auto (default), 4T~7T.
Row Cycle Time
Options are: Auto (default), 11T~42T.
RAS to RAS Delay
Options are: Auto (default), 4T~7T.
Bank Interleaving
Enables or disables memory bank interleaving. Enabled allows the system to simultaneously access dif-
ferent banks of the memory to increase memory performance and stability. (Default: Enabled)
Channel interleave
Enables or disables memory channel interleaving. Enabled allows the system to simultaneously access
different channels of the memory to increase memory performance and stability. (Default: Enabled)
******** System Voltage Optimized ********
System Voltage Control
Determines whether to manually set the system voltages. Auto lets the BIOS automatically set the
system voltages as required. Manual allows all voltage control items below to be configurable. (Default:
Auto)
DDR3 Voltage Control
Allows you to set memory voltage.
Normal
+0.050V ~ +0.750V The adjustable range is from +0.050V to +0.750V.
Note: Increasing memory voltage may result in damage to the memory.
NorthBridge Volt Control
Allows you to set the North Bridge voltage.
Normal
+0.1V ~ +0.3V
SouthBridge Volt Control
Allows you to set the South Bridge voltage.
Normal
+0.1V ~ +0.3V
CPU NB VID Control
Allows you to set the CPU Northbridge VID voltage. Auto sets the CPU Northbridge VID voltage as re-
quired. The adjustable range is dependent on the CPU being installed. (Default: Normal)
Note: Increasing CPU voltage may result in damage to your CPU or reduce the useful life of the CPU.
BIOS Setup
Supplies the memory voltage as required. (Default)
Supplies the North Bridge voltage as required. (Default)
The adjustable range is from +0.1V to +0.3V.
Supplies the South Bridge voltage as required. (Default)
The adjustable range is from +0.1V to +0.3V.