Right Crankcase Cover Removal; A.c.g. Set Removal; Right Cover Bearing Inspection - Eton VECTOR ST 250 Service Manual

Hide thumbs Also See for VECTOR ST 250:
Table of Contents

Advertisement

10-3 Right Crankcase Cover
11 bolts
Removal
Remove left
footrest.
Drain out the engine oil and coolant, and then
remove coolant hoses.
Remove water pump cover (4 bolts).
Remove 11 bolts from the right crankcase cover.
Remove the right crankcase cover.
Remove dowel pin and gasket.
Water pump cover bolts
2 screws

10-4 A.C.G. Set Removal

Remove 2 mounted screws from pulse generator
and then remove it.
Remove 3 screws from right crankcase cover and
then remove generator coil set.
3 screws
Cir clip
10-5 Right Cover Bearing
Inspection
Rotate the bearing with finger to check if the
bearing rotation is in smooth and silent.
Check if the bearing outer parts are closed and
fixed. Replace it if necessary.
Remove the cir clip, and then remove bearing.
Special tool:
Inner bearing puller
86

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

250

Table of Contents