Float Chamber Disassembly And Inspection - Eton VECTOR ST 250 Service Manual

Hide thumbs Also See for VECTOR ST 250:
Table of Contents

Advertisement

5-7 Float Chamber
Disassembly
Remove 3 mounting screws and remove float
chamber cover.
Remove the fuel level plate, float pin, float and
float valve.
Inspection
Check float valve and valve seat for damage,
blocking.
Check float valve for wearing, and check valve
seat face for wear, dirt.
Caution
In case of worn out or dirt, the float valve and
valve seat will not tightly close causing fuel level
to increase and as a result, fuel flooding. A worn
out or dirty float valve must be replaced with a
new a new one.
Float
Fuel level plate
Float
Check for wear or damage
29
3 Screws
Float valve
Pin
Float valve
Pin