Connect Power Cables
1. Verify that the P6 backplane power cable is routed from the power supply to the backplane
board and is connected to the white 6-pin connector.
2. Connect the main server board power cable to the white 24-pin connector on the server board.
Firmly press the two connectors together until they are fully seated.
Install the Fan module
CAUTION
When installing the fan module, avoid pinching cables routed in the area.
1. Note the raised tabs on the chassis floor and the corresponding holes in the bottom of the fan
module.
2. Lower the fan module until it is just above the chassis floor.
3. Align the holes in the fan module with the raised tabs on the chassis and lower the fan module
onto the floor.
4. While pressing down on the fan module, slide it in the direction of arrow (2) until the latch
snaps into place.
Assembling the System
B
A
Figure 13. Connecting the Main Power Cable
B
OM14616
29