Replacing the Fan Module

1. Before removing the cover to work inside the system, observe the safety guidelines on page 45.
2. Remove the cover from the chassis.
3. Remove the full-height PCI riser card.
4. Remove the flex circuit cable retention clip.
5. Disconnect the flex circuit cable from the backplane.
6. At the end of the fan module closest to the chassis centerline, push on the tab to release it from
the chassis (A).
7. While pushing on the tab, lift up on the module to clear the retention stub.
8. Slide the module towards the power supply until it comes free.
9. Lift the fan module out of the chassis.
10. Align the holes in the new fan module with the raised tabs on the chassis and lower the fan
module onto the chassis floor.
11. Slide the fan module toward the chassis sidewall until it has locked in place.
12. Plug the fan cables into the server board system fan connectors.
13. Make sure the USB cable is routed along the top of the fan module.
14. Connect the flex circuit cable to the backplane.
15. Install the flex circuit cable retention clip.
16. Install the full-height PCI riser card.
17. Replace the chassis cover.
58
3
2
1
A
Figure 40. Removing the Fan module
Intel SR2300 Chassis Subassembly Product Guide
C
B
OM14088