Flex Bay; 500 Watt Redundant Power Supply; 480 Watt Power Supply; System Cooling - Intel SE7500WV2 - Server Chassis - SR2300 Product Manual

Subassembly product guide
Hide thumbs Also See for SE7500WV2 - Server Chassis - SR2300:
Table of Contents

Advertisement

NOTE
Drives can consume up to 17W of power each. Drives must be specified to
run at a maximum ambient temperature of 50 °C.

Flex Bay

The flex bay can be used with either the optional DVD/FDD module, CD-ROM/FDD module, or a
seventh hot swappable SCSI HDD.
The DVD/CD-ROM/FDD module may only be inserted or removed from the flex bay when system
power is turned off. It is NOT hot swappable. For information on installation, see "Installing a
DVD drive/FDD or CD-ROM drive/FDD Module" on page 40.

500 Watt Redundant Power Supply

The power supply consists of the power supply bay and one power supply module. A second
power supply module can be purchased to provide a redundant, 1+1 system. With either
configuration, the power supply provides 500 W of power and is designed to minimize EMI. The
power supply operates within the following voltage ranges and is rated as follows:
100-120 V∼ at 50/60 Hertz (Hz); 5.2 A maximum
200-240 V∼ at 50/60 Hz; 2.6 A maximum
The power subsystem supports implementation of remote management features including remote
enable that permits power to be activated from a variety of sources.

480 Watt Power Supply

The power supply consists of the power supply; no modules are available. The power supply
provides 480W of power and is designed to minimize EMI. The power supply operates within the
following voltage ranges and is rated as follows:
100-120 V∼ at 50/60 Hz; 6.8 A maximum
200-240 V∼ at 50/60 Hz; 3.4 A maximum
The power subsystem supports implementation of remote management features including remote
enable that permits power to be activated from a variety of sources.

System Cooling

The chassis includes three 60-mm non-hot-swappable system fans for cooling the processor(s), hard
drives, and add-in cards. A fourth fan may be added to provide cooling redundancy for system
components. The system fans are mounted in a fan module located in the middle of the chassis to
pull cooling air through the chassis. The power supply contains a single fan for cooling.
14
Intel SR2300 Chassis Subassembly Product Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr2300

Table of Contents