HP StorageWorks 12000 User Manual page 186

Hp storageworks 12000 gateway virtual library system user guide (ah814-96015, september 2010)
Hide thumbs Also See for StorageWorks 12000:
Table of Contents

Advertisement

HP Systems In-
Internal health
sight Display LED
LED color
and color
Processor failure,
Red
socket X (amber)
Amber
PPM failure, slot X
Red
(amber)
FBDIMM failure, slot
Red
X (amber)
Amber
FBDIMM failure, all
slots in one bank
Red
(amber)
Online spare
Amber
memory (amber)
Online spare
memory (flashing
Red
amber)
Online spare
Green
memory (green)
Mirrored memory
Amber
(amber)
Mirrored memory
Red
(flashing amber)
Mirrored memory
Green
(green)
Overtemperature
Amber
(amber)
Red
Riser interlock (am-
Red
ber)
Amber
Fan module (amber)
Red
186
Component Identification
Status
One or more of the following conditions may exist:
Processor in socket X has failed.
Processor X is required yet not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Processor in socket X is in a pre-failure condition.
One or more of the following conditions may exist:
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding processor
is installed.
FBDIMM in slot X has failed.
FBDIMM in slot X is in a pre-failure condition.
One or more FBDIMMs has failed. Test each bank of FBDIMMs
by removing all other FBDIMMs. Isolate the failed FBDIMM by
replacing each FBDIMM in a bank with a known working FB-
DIMM.
Bank X failed over to the online spare memory bank.
Invalid online spare memory configuration.
Online spare memory enabled and not failed.
Bank X failed over to the mirrored memory bank.
Invalid mirrored memory configuration.
Mirrored memory enabled and not failed.
The Health Driver has detected a cautionary temperature level.
The server has detected a hardware critical temperature level.
PCI riser cage is not seated.
One fan is failed or removed.
Two or more fans have failed or are removed.