Brocade Communications Systems 8 Reference Manual page 295

Fabric os mib reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Variables
connUnitId
A connUnit has been deleted from this agent.
Recommended severity level (for filtering)- warning.
Not implemented.
connUnitEventTrap
Enterprise
fcmgmt
Variables
connUnitEventId, connUnitEventType, connUnitEventObject, connUnitEventDescr
An event has been generated by the connectivity unit.
Recommended severity level (for filtering)- info.
Sample trap output for Fabric OS v6.1.0.
Refer to the
connUnitSensorStatusChange
Enterprise
fcmgmt
Variables
connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply, temperature)
present in the connectivity unit changes.
Sample trap output for Fabric OS v6.1.0.
Refer to the Fabric Watch Administrator's Guide for information on configuring thresholds that
generate these traps.
connUnitPortStatusChange
Enterprise
fcmgmt
Variables
connUnitPortStatus, connUnitPortState
Overall status of the connectivity unit changed. Recommended severity level (for filtering)- alert.
This trap sends the instance of connUnitPortName as part of the trap; the instance string is NULL,
if the port name is not defined for the specified port.
Fabric OS MIB Reference
53-1001768-01
connUnitEventId.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = 354
connUnitEventType.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = other(2)
connUnitEventObject.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = null
connUnitEventDescr.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = FW-1425
Switch status changed from MARGINAL to HEALTHY.
"swEventTrap 1.3.6.1.4.1.1588.2.1.1.1.0.4"
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
connUnitEventTrap
for more details.