Troubleshooting - Central Pneumatic 92917 Set Up And Operating Instructions Manual

Coil roofing nailer 3/4” to 1-3/4” fastener length capacity
Table of Contents

Advertisement

Problem
Insufficient
1.
fastener depth.
2.
3.
4.
5.
Fasteners drive
1.
too deeply.
2.
Tool cycles
1.
without firing
fastener.
2.
3.
4.
5.
Frequent
Incorrect fastener type.
jamming.
Severe air
1.
leakage.
(Slight air leakage
is normal,
2.
especially on
older tools.)
3.
4.
Follow all safety precautions whenever diagnosing or servicing the tool.
disconnect air supply before service.
REV 09h
SKU 92917
For technical questions, please call 1-800-444-3353.
93253

Troubleshooting

Possible Causes
Incorrect tool depth setting.
Not enough air pressure.
Incorrect lubrication or not
enough lubrication.
Blocked air inlet screen (if
equipped).
Mechanism contaminated.
Incorrect tool depth setting.
Too much air pressure.
Jammed fastener.
Tool empty.
Incorrect fasteners used.
Canister dirty or not lubricated
properly.
Insufficient air flow.
Cross-threaded housing
components.
Loose housing.
Damaged valve or housing.
Dirty, worn or damaged valve.
Likely Solutions
1.
Adjust depth setting, if available.
2.
Check for loose connections and make
sure that air supply is providing enough air
pressure (PSI) to the tool's air inlet. do not
exceed maximum air pressure.
3.
Lubricate using air tool oil and grease
according to directions.
4.
Clean air inlet screen of buildup.
5.
Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply
as stated in Initial Set Up: Air Supply.
1.
Adjust depth setting, if available.
2.
Reduce air supply pressure (PSI).
1.
Clear jammed fastener according to Clearing
Jams instructions.
2.
Fill with correct fasteners.
3.
Empty, then fill with correct fasteners.
4.
Clean and lubricate canister and pusher.
5.
Check for loose connections and make
sure that air supply is providing enough air
flow (CFM) and pressure (PSI) to the tool's
air inlet. do not exceed maximum air
pressure.
Confirm fastener diameter, type, length, angle,
and collation type. Correct as needed.
1.
Check for incorrect alignment and uneven
gaps. If cross-threaded, disassemble and
replace damaged parts before use.
2.
Tighten housing assembly. If housing cannot
tighten properly, internal parts may be
misaligned.
3.
Replace damaged components.
4.
Clean or replace valve assembly.
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

93253Coil roofing nailer

Table of Contents