0X1A Effect Information Response; 0X1B Bank Label Dump - Lexicon PCM 90 - MIDI IMPLEMENTATION DETAILS Midi Implementation Manual

Table of Contents

Advertisement

PCM 90 MIDI Implementation Details
0x1A
Effect Information Response
PCM 90 to host only. This dump allows a remote master to get information about any of the effects in the
box.
Byte #
Byte Value
1
F0
2
06
3
08
4
0iii iiii
5
0x1A
6
0iii iiii
7
0iii iiii
8-23
0iii iiii
24-35
0iii iiii
36
0xF7
0x1B
Bank Label Dump
This is a bidirectional dump which sets/gets bank and row labels.
Byte #
Byte Value
1
F0
2
06
3
08
4
0iii iiii
5
0x1B
6
0iii iiii
7- 13
0iii iiii
14- 24
0iii iiii
25- 35
.........
36- 46
.........
47- 57
.........
58- 68
.........
69
0xF7
20
Description
SysEx ID
Lexicon ID
PCM 90 ID
Device ID
Effect Information
Bank #
Program #
Algorithm Name
Program Name
End of SysEx
Description
SysEx ID
Lexicon ID
PCM 90 ID
Device ID
Bank labels
Bank
ASCII Bank Label
ASCII Row Label 0
Row label 1
Row label 2
Row label 3
Row label 4
End of SysEx
Notes
A bank # of 0x7F AND prog # of 0x7F indicates the current
program.
16 Byte string
12 Byte string
Notes
Source bank if sent by PCM 90. Target bank if received by
PCM 90. Appendix C: MIDI Bank Assignments.
7 Byte string
11 Byte string
11 Byte string
11 Byte string
11 Byte string
11 Byte string
Lexicon

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm 90

Table of Contents