Yaesu FT-270R Operating Manual page 77

Vhf fm transceiver
Hide thumbs Also See for FT-270R:
Table of Contents

Advertisement

Set Mode Item 8 BSY.LED
Function: Enables/Disables the BUSY LED while the Squelch is open.
Available Values: LED. ON/LED.OFF
Default: LED. ON
Set Mode Item 9 CLK.SFT
Function: Shifting of the CPU clock frequency.
Available Values: SFT.OFF/SFT. ON
Default: SFT.OFF
This function is only used to move a spurious response "birdie," should it fall on a desired
frequency.
Set Mode Item 10 CWID
Function: Enables/disables the CW identifier during ARTS operation.
Available Values: TX OFF/TX ON
Default: TX OFF
Set Mode Item 11 CW WRT
Function: Programs and activates the CW Identifier (used during ARTS operation).
See page 52 for details.
Set Mode Item 12 DC VLT
Function: Indicates the DC Supply Voltage.
Set Mode Item 13 DCS.COD
Function: Setting of the DCS code.
Available Values: 104 standard DCS codes
Default: DCS.023
Set Mode Item 14 DCS.N/R
Function: Enables/Disables "Inverted" DCS
code decoding.
Available Values: T/RX N, RX R, TX R,
T/RX R
Default: T/RX N
Set Mode Item 15 DT DLY
Function: Setting of the DTMF Autodialer Delay Time.
Available Values: 50MS/100MS/250MS/450MS750MS/1000MS
Default: 450MS
Set Mode Item 16 DT SPD
Function: Setting of the DTMF Autodialer Sending Speed.
Available Values: 50MS (high speed)/100MS (low speed)
Default: 50MS
FT-270R O
M
S
M
ET
DCS CODE
023 025 026 031 032 036 043 047 051 053
054 065 071 072 073 074 114 115 116 122
125 131 132 134 143 145 152 155 156 162
165 172 174 205 212 223 225 226 243 244
245 246 251 252 255 261 263 265 266 271
274 306 311 315 325 331 332 343 346 351
356 364 365 371 411 412 413 423 431 432
445 446 452 454 455 462 464 465 466 503
506 516 523 526 532 546 565 606 612 624
627 631 632 654 662 664 703 712 723 731
732 734 743 754 –
M
ENU
ODE
73