Honeywell TE923W - Deluxe Weather Station User Manual

Honeywell TE923W - Deluxe Weather Station User Manual

Professional weather station with remote control
Hide thumbs Also See for TE923W - Deluxe Weather Station:

Advertisement

Quick Links

HONEYWELL
TE923W
PROFESSIONAL WEATHER STATION
WITH REMOTE CONTROL
USER MANUAL
Date: 7-4-08
1
TE923W IM1(ENG) HONEYWELL R.pmd
1
4/11/08, 5:21 PM

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TE923W - Deluxe Weather Station

  • Page 1 HONEYWELL TE923W PROFESSIONAL WEATHER STATION WITH REMOTE CONTROL USER MANUAL Date: 7-4-08 TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:21 PM...
  • Page 2: Table Of Contents

    Temperature and Humidity Mode............Rain Mode ....................Wind Mode ..................... Maintenance.................... Troubleshooting ..................PRECAUTIONS ..................Appendix - City Codes ................Specifications ..................FCC STATEMENT ................. DECLARATION OF CONFORMITY ........... STANDARD WARRANTY INFORMATION ........TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:21 PM...
  • Page 3: Introduction

    Introduction Thank you for selecting the Honeywell Professional Weather Station with remote control. This compact and easy-to-use product features a wide variety of time and weather data, such as precise atomic time, perpetual calendar, air temperature, relative humidity, barometric pressure, wind speed and direction, rainfall, UV levels and etc.
  • Page 4: Standard Package Contents

    Anemometer arm Anemometer base PC Software 4 screws for securing rain gauge to the flat surface; Mounting hardware 4 screws for securing anemometer to vertical surface 2m (6ft) USB cable PC connection cable TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM...
  • Page 5: Installation

    - Mounting pole for anemometer (optional) - Small paper clip for reset Installation The Honeywell Professional Weather Station TE923W operates at 433MHz radio frequency, so no wire installation is required between the main unit (receiver) and the remote weather sensors (transmitters).
  • Page 6: Before You Begin

    C) and below. IMPORTANT: Make sure that the remote weather sensors are easily accessible for cleaning and maintenance. We recommend cleaning the remote weather sensors periodically, as the dirt and debris may affect sensors accuracy. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM...
  • Page 7: Uv (Ultraviolet) Sensor

    Secures sensors in the sensor holder on the flat surface E. UV SENSOR LID Covers UV sensor and seals battery compartment F. BATTERY COMPARTMENT Holds two AA-size batteries G. BATTERY COMPARTMENT DOOR Covers two AA-size batteries TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM...
  • Page 8 • Secure the sensor in a location with a maximum sun exposure throughout the day. Placement tips: The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM...
  • Page 9: Thermo-Hygrometer Sensor

    Avoid any areas collecting and radiating a heat from the sun, such as metal, brick or concrete structures, paving, patios and decks. • The international standard for the valid air temperature measurements is 4 feet (1.25meters) above the ground. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM...
  • Page 10: Rain Gauge

    Ensures level rain gauge mounting for proper operation H. Bucket see-saw mechanism Collects the rainfall in one of its containers and self-empties once full I. Protective screen Protects the rain gauge funnel from debris TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:25 PM...
  • Page 11 To avoid the rain shadow effects, place the rain gauge horizontally, on the distance corresponding to two to four times the height of any nearby obstruction. • It is important to locate the unit where rain can flow freely away. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:25 PM...
  • Page 12: Anemometer (Wind Sensor)

    Holds wind cups on the anemometer arm F. BATTERY COMPARTMENT Holds 2 AA-size batteries G. WALL MOUNT SCREW OPENINGS Allows securing the anemometer in place H. BATTERY COVER Allows securing 2 AA size batteries on the anemometer base TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 13 • The anemometer should be mounted in an open area with a free air flow; away from the nearby trees, buildings or other structures. • For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 14: Main Unit

    • Light sensor detects low light conditions and LCD lights up automatically when adapter is connected • Infrared remote control of all display functions Power • AC/DC adapter for automatic remote control • 4 AA batteries TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 15: Battery Installation

    IMPORTANT: If not set during the initial setup, the altitude cannot be adjusted or set at any other time. In order to set the altitude, you will have to restart the main unit completely. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 16: Buttons And Controls

    - Changes the temperature and humidity channel- Enables the temperature CHANNEL and humidity channel auto-scan mode - Enables a backlight for 5 seconds- Snoozes the alarms LIGHT/ SNOOZE TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 17 - Selects the Sunrise/Sunset Mode - Selects the Clock and Alarm Mode Clock and Alarm Mode - Selects 24 hour History Bar-chart. Change Bar-chart - Alternates between Pressure, Channel 1 Temperature, Display or Channel 1 Humidity TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM...
  • Page 18: Operating Mode Descriptions

    Note: For altitude display of 99o this is actually 990 feet, etc. UV Window Displays: • UV index or Minimum Ultraviolet Exposure • Daily Maximum • Weekly Maximum • Remote UV sensor battery status TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 19 • Remote Thermo-Hygrometer sensor battery status Cycling Display Dew-point Tempature Sensor Battery Status Channel Humidity Channel Temp. Channel and Reception status Temp. Alert Comfort Level Min-Max Display Tempature and Humidity Mode Icon Indoor Temp. Indoor Humidity TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 20 • Wind Chill temperature • Temperature at place of anemometer • Wind direction • Wind speed • Wind gust speed • Alert for wind speed and wind gust speed • Remote anemometer battery status Needle TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 21: Customizing Your Weather Station

    USB cable. • Install the software provided with the weather station according to the instructions in the software manual. • Connect the main unit to the computer using the USB cable provided. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 22: Using Different Weather Modes

    Wait at least 5 minutes after initial set up to view a pressure or altitude information. Briefly press SET button to alternate between the sea level pressure, local pressure and local altitude settings. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 23 • Press UP or DOWN selecting from today’s date a future (+) or past (-) days and the corresponding moon phase will be displayed. Press and hold either button for a quick advance. • To exit, press MEMORY button. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 24 Light Rain Heavy Rain Unstable Weather Snow Note: The weather forecast accuracy is approximately 70%. Display shows forecasted, not current conditions. The SUNNY icon indicates clear weather, even when displayed during the night-time. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:27 PM...
  • Page 25: Uv Mode

    (from 15 to 90 minutes) before the weekday or single alarm, if channel 1 temperature falling to freezing and below. Note: The snooze duration for listed alarms can also be programmed up to 15 minutes. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 26 • Time with the Day of the week • Time for UTC (Coordinated Universal Time) • Time with the City abbreviation • Time with the Seconds • Month/ Day/ Year or Day/ Month/ Year. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 27 Press ALARM/CHART to disable the alarm (s). Note: For weekday alarm, pressing ALARM/CHART will only disable the alarm for the current day. The alarm will activate again on the next day, Monday through Friday. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 28 If reception is disabled, the triangular tower icon will disappear. Icon Atomic Time Reception Strength Undefined data (Flashing) No reception for 24 hours Weak signal, but can be decoded Strong signal TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 29: Sunrise/Sunset Mode

    • Press UP or DOWN to adjust the date. Press and hold either button for fast digits advance. • The corresponding sunrise and sunset times will be displayed for the selected date. • Press MEMORY or SET to return display to the Sunrise/Sunset Mode. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 30: Temperature And Humidity Mode

    This means that after the temperature reaches the alert temperature, it will have to fall below the alert temperature plus the deviation (0.5°C) to activate the alert. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 31 Resetting the Remote Temperature and Humidity Memory In the Temperature and Humidity Mode, press and hold the MEMORY button to clear memory for all channels. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 32: Rain Mode

    • If the alert is disabled, the “OFF” will be displayed; otherwise the rainfall alert value will be shown. • When the rainfall alert is displayed, press the UP or DOWN to enable or disable it. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 33: Wind Mode

    “DAILY MAX” displayed, a gust speed with a “GUST” displayed and a daily maximum gust speed with a “GUST DAILY MAX” displayed. Resetting the Wind Statistics Memory In the Wind Mode, press and hold MEMORY to reset all wind statistics. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 34: Maintenance

    Never use any abrasive cleaning agents and solvents. Do not immerse any units with electronic parts in water or under running water. Anemometer Check if the wind vane and wind cups can spin freely and are free from dirt, debris and spider webs. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 35: Troubleshooting

    Do not tamper with the product’s internal components. Doing so will invalidate the warranty and may cause damage. The product contains no user-serviceable parts. • Use only fresh batteries. Do not mix new and old batteries. • Read the user’s manual thoroughly before operating the product. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 36: Appendix - City Codes

    Milwaukee, Wis. Minneapolis, Minn. New Orleans, La. Oklahoma City, Okla. San Antonio, Tex. St. Louis, Mo. Atlanta, Ga. Boston, Mass. Baltimore, Md. Cleveland, Ohio Columbus, Ohio Cincinnati, Ohio Washington, D.C. Detroit, Mich. Havana, Cuba TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 37 Caracas, Venezuela Calcutta, India (as Kolkata) Córdoba, Argentina Copenhagen, Denmark Cape Town, South Africa New Delhi, India Dakar, Senegal Dublin, Ireland Durban, South Africa Kinshasa, Congo Frankfurt, Germany Glasgow, Scotland Guatemala City, Guatemala TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 38 Rio de Janeiro, Brazil Reykjavík, Iceland Rome, Italy Santiago, Chile Shanghai, China Singapore, Malasia Sofia, Bulgaria São Paulo, Brazil Salvador, Brazil Sydney, Australia Tokyo, Japan Tripoli, Libya Vienna, Austria Warsaw, Poland Zürich, Switzerland TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 39 SM = DST starts on third Sunday of September at Midnight local standard time (0:00 >> 01:00) and ends on last Sunday of March at 2:00 AM local daylight time (02:00 >> 01:00). TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 40: Specifications

    Range: 0 UVI to 36UVI (15.4 MED/hour) Resolution : 0.1UVI (0.1 MED/h) Accuracy: 1UVI + 10% Transmitting Interval: 300 seconds Wind Direction Range: 0° to 360° Resolution: 22.5° Accuracy: 11.25° Starting Threshold: 3mph (4.8 Km/h) Transmitting interval: 33 seconds TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 41 Remote Rain gauge: 6.49 (L) x 6.89 (H) x 4.72 (D) inches / 165 (L) x 175 (H) x 119 (D) mm IR Remote Control: 1.61 (L) x 5.94 (H) x 0.86 (D) inch / 40 (L) x 150 (H) x 22 (D) mm TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 42: Fcc Statement

    The information above is not to be used as a contact for support or sales. Please call our customer service hotline (refer to the Standard Warranty Information) for all injuries instead. TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...
  • Page 43: Standard Warranty Information

    Hideki Electronics, Inc. reserves the right to repair or replace the product at our option. Copyright (2008) Hideki Electronics Inc. All Rights Reserved. The Honeywell Trademark is used under license from Honeywell International Inc.
  • Page 44 TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:28 PM...